ReeR – ADMIRAL

ReeR – ADMIRAL

Tip 4, SILCL3, PL e, Kat. Entegre bankacılık fonksiyonlarına sahip 4 Emniyetli Işık Perdesi

Amiral Tip 4 güvenlik ışık perdeleri ailesi, yüksek riskli endüstriyel uygulamaların çoğunun korunması için ideal bir çözümdür.
İki bariyeri ve Floating Blanking’li modellerin kademeli olarak bağlanması için Master / Slave modelleri de dahil olmak üzere ürün yelpazesinin genişliği.
Uzun Menzilli modeller 2, 3 ve 4 ile kirişlerin maks. 60 m, İkili Model Kirişler maks. 80 m.

Safety level Type 4 according to IEC 61496-1; IEC 61496-2
SILCL 3 according to IEC 62061
PL e -Cat. 4 according to ISO 13849-1
Protected heights (m) 160 … 1810 (for some resolution up to 2160
Response time (ms) 6 … 27
Safety outputs 2 PNP – 500 mA at 24 VDC with short-circuit, overload, polarity reversal protection
Signalling Seven-segment display
LEDs for light curtain’s status and diagnostic
On the receivers of all models, a yellow LED turns ON when the received beam signal intensity is weak
Power supply (VDC) 24 ± 20%
Max. cable length (m) 100
Operating temperature (°C) 0 … 55
Protection rate IP 65
Fastening modes Back slot, side slot or to the top and lower end with swivel brackets
Cross section (mm) 35 x 45
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • IEC 61496-1 (ed. 3) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
  • IEC 61496-2 (ed. 3) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
  • IEC 62061 (ed. 1) (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • ISO 13849-1:2006 (Cat. 4, PL e)Safety of machinery: safety-related parts of control systems. Part 1: General principles for design
  • EN 50178:1997 Electronic equipment for use in power installations
  • EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
  • UL (C+US) mark for USA and Canada
  • Marchio TS per Taiwan
  • ANSI / UL 1998: Safety Software in Programmable Components
  • Press Brakes
  • Presses
  • Punching and dinking machines
  • Cutters and shears
  • Robotised areas
  • Assembly lines
  • Palletising system
ADMIRAL AD

Otomatik Başlat / Yeniden Başlat

ADMIRAL AX

Dahili kontrol fonksiyonu ile

ADMIRAL AX LR

Uzun menzilli modeller

ADMIRAL AX LR DB

Yenilikçi çift kirişli Amiral Uzun Menzilli özel versiyonu

ADMIRAL AX BK

Dahili kayan boşluk fonksiyonu ile

ADMIRAL AXM - AXS

Dahili kontrol fonksiyonlarına sahip Master / Slave modelleri

79 Ratio Agency