ReeR – EOS2

ReeR – EOS2

Type 2 compact safety light curtains, SIL1, SILCL1, PL c, Cat. 2

EOS2 is a compact light curtain range with competitive performance and innovative features.

Includes models with integrated safety functions, including self-monitoring of static outputs, control of external contactors (EDM) and automatic/manual selectable restart.

Minimal cross section: 28 x 30 mm

Master/Slave models for cascade connection of two or three curtains

No blind area on one side. The position of first beam ensures that the sensitive area extends to end of the light curtain. The protected area extends until the light curtain end maintaining the resolution.

Minimal blind area on connector side. The solution with two L-mounted light curtains, e.g. Master/Slave, maintains 40 mm resolution in corner (models with resolution up to 40 mm).

youtube
Safety level Type 2 according to EN 61496-1; IEC 61496-2
SIL 1 according to IEC 61508
SILCL 1 according to IEC 62061
PL c – Cat. 2 according to EN ISO 13849-1
Protected heights (mm) 160 … 2260
Response time (ms) 2,5 … 18,5
Safety outputs 2 PNP – 400 mA at 24 VDC with short-circuit, overload, polarity reversal protection
Signalling LEDs for light curtain’s status and diagnostic
On the receivers of 14 mm resolution and H models a blue LED turns ON when the received beam signal intensity is weak.
Power supply (VDC) 24 ± 20%
Max. cable length 100 m
Operating temperature (°C) -30 … 55 – Standard models with range up to 12 m
-20 … 55 – H models with range up to 20 m
Protection rate IP 65 and IP 67
Fastening modes back slot tothe top and lower end by rotating brackets SFB E180 (optional)
Cross section (mm) 28 x 30
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • EN 61496-1:2013 (Type 2) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
  • EN 61496-2:2013 (Type 2) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
  • IEC 61508-1 (ed. 2) (SIL 1) Functional safety of electrical/electronic programmable electronic safety related systems. General requirements
  • IEC 61508-2 (ed. 2) (SIL 1) Functional safety of electrical/electronic/programmable electronic safety related systems. Requirements for electrical/electronic/programmable electronic safety-related systems
  • IEC 61508-3 (ed. 2) (SIL 1) Functional safety of electrical/electronic programmable electronic safety related systems. Software requirements
  • IEC 61508-4 (ed. 2) (SIL 1) Functional safety of electrical/electronic programmable electronic safety related systems. Definitions and abbreviations
  • IEC62061:2005/A2:2015 (SILCL 1) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • EN ISO 13849-1:2015 (Cat. 2, PL c) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
  • UL (C+US) mark for USA and Canada
  • TS-Mark for Taiwan
  • ANSI / UL 1998: Safety Software in Programmable Components
  • Assembly lines
  • Automatic warehouses
  • Wood-working machines
  • Assembly machines, also having a small size
EOS2 A
With automatic Start/Restart
EOS2 X
With built-in control functions
EOS2 XS - XM - XS2
Master/Slave models whit built-in control functions
EOS2 X WTH/WTHF
Watertight enclosure, Food Graded, IP 69K Certified

79 Ratio Agency