ReeR – VISION

ReeR – VISION

Type 2, SILCL1, PL c, Cat.2 safety light curtain

The VISION Type 2 family of safety light curtains is the ideal solution for the protection of the majority of industrial applications in Category 2.

Test function, activated automatically and periodically, without interruption of the operation of the machine being controlled.

The breadth of the range, including Master / Slave models for cascade connection of two in Muting function.

Vision light curtains may be connected to the dedicated safety interfaces series AD SR, or directly to contactors actuated and controlled by the light curtain, or to MOSAIC or to suitable commercial safety modules or safety PLCs.

Safety level Type 2 according to IEC 61496-1; IEC 61496-2
SILCL 1 according to IEC 62061
PL c – Cat. 2 according to EN ISO 13849-1
Safety outputs 2 PNP auto-controlled – 500 mA at 24 VDC with short-circuit, overload, polarity reversal protection
Signalling LEDs for light curtain’s status and diagnostic
Power supply (VDC) 24 +/-20%
Max. cable length (m) 100
Operating temperature (°C) 0 … +55
Protection rate IP 65
Fastening modes Back slot, side slot or to the top and lower end with swivel brackets
Cross section (mm) 35 x 45
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • IEC 61496-1 (ed. 3) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
  • IEC 61496-2 (ed. 3) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
  • IEC 62061 (ed. 1) (SILCL 1) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • EN ISO 13849-1:2008 (Cat. 2, PL c) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
  • EN 50178:1997 Electronic equipment for use in power installations
  • EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
  • UL (C+US) mark for USA and Canada
  • ANSI / UL 1998: Safety Software in Programmable Components
    • Palletisers and depalletisers
    • Handling and storage systems
    • Assembly and disassembly lines
    • Robotised areas
    • Wood and marble processing machines
    • Welding systems and robots
    • Long distance protection and perimetre protection using defection mirrors (SP and FMC columns)

    Note: where the risk analysis allows the use of category 2 safety equipment

VISION V L
With automatic Start/Restart
VISION V H

High range models with automatic Start/Restart

VISION VX
With built-in control functions
VISION VX LR
High range models with built-in control function
VISION VXM - VXS
Master/Slave models with built-in control functions
VISION VXL

Entry level with built-in control function

VISION MXL - MXL
With integrated Muting function
VISION MXL L
With 2 integrated photoelectric Muting sensors with crossed beams – Only exit access control
VISION MXL T
With 2 integrated photoelectric Muting sensors with crossed beams – Entry/Exit access control
VISION VX WT/WTH
IP 67 watertight enclosure

79 Ratio Agency